Source: Wolf Integrated Modules (new 2015) error code answer pages
E10 is a dry start. Wolf says clean the pan interior and add liquid.
E10 is one of the few codes in this family where Wolf gives hands-on steps that have nothing to do with the breaker. The cause line is “Dry start at startup,” and the page ties it to a temperature gap between the two probes in the pan.
At a glance
| Code | E10 |
|---|---|
| Appliance | Integrated Modules |
| What it means | Wolf lists E10 as a dry start at startup, based on how far the steam fill RTD runs above the main RTD in the first minutes. |
| First thing to try | Clean debris or build-up from the bottom interior of the pan. |
Thresholds by module
- SM15TF/S: steam fill RTD is 18°F above the main RTD during the first 90 seconds.
- FM15TF/S: steam fill RTD is 30°F above the main RTD during the first 120 seconds.
What to do first
- Clean debris or build-up from the bottom interior of the pan.
- Add liquid to the pan.
- Start the module again.
Let the pan cool before reaching into it. This is a sensible precaution of ours, not a line from the page.
If it keeps appearing
Wolf states that no further customer troubleshooting advice is given and to contact Factory Certified Service. Note that no breaker cycle is advised here.
Closely related
A cleaning note
Build-up on the bottom of a pan can insulate one probe from the liquid. That is our plain-language reading of why Wolf asks you to clean it. Use a non-scratch method, wait until the pan is cool, and refill with liquid before you restart the module.